Process Control and Instrumentation Questions

Practice Process Control and Instrumentation MCQs with answers and explanations. Page 9 of 17.

Category
Chemical Engineering
Topic
Process Control and Instrumentation
Page
9 / 17
Mode
Practice

Questions

Open any question to view the answer and explanation.

Thermal-conductivity-type continuous flue gas analyzer: among common flue gas constituents CO2, N2, O2, and CO, which has the highest thermal conductivity and therefore produces the greatest conductive signal change?
Open
View answer
Second-order LTI system — choose the standard canonical transfer function form In classical process control, the standard form of a linear time-invariant second-order system is expressed using the undamped natural frequency (ω_n) and the damping ratio (ζ). Which of the following expressions represents this canonical transfer function (unity static form)?
Open
View answer
Seebeck effect in thermocouples — what does the generated emf depend on? In practical thermocouple measurements, the electromotive force (emf) is determined by which temperature relationship between the two junctions?
Open
View answer
Frequency response of a first-order system (τ = 1 min) A first-order process with time constant τ = 1 minute is tested at input frequency ω = 1 rad/min. What is the steady-state phase shift (in degrees) between output and sinusoidal input?
Open
View answer
Stability of a system with a double pole at the origin A linear system has a double pole at s = 0. Which time-domain behaviour explains why such a system is unstable?
Open
View answer
Photoconductive (photoresistive) transducers — what do they actually sense? A photoelectric device whose resistance varies in direct proportion to incident light is called a photoconductive cell. Photoelectric transducers are therefore used to measure parameters that can be converted into controlled changes in what primary quantity?
Open
View answer
Anatomy of a pH meter — how many electrochemical cells? A standard laboratory/industrial pH meter uses a measuring (glass) electrode and a reference electrode. Considering their electrochemical arrangement, how many cells are effectively involved?
Open
View answer
Limits of non-contact thermometry — where can’t radiation thermometers be used? A radiation (optical/infrared) thermometer measures temperature from emitted radiation without touching the target. In which of the following cases is such a thermometer not suitable?
Open
View answer
Purpose of thermowells in temperature measurement In industrial service, thermowells are installed primarily to achieve which of the following goals when measuring temperature with probes or thermocouples?
Open
View answer
High-temperature thermocouples in oxidising atmospheres (~1600°C) Which thermocouple type is most suitable for measuring about 1600°C in an oxidising environment?
Open
View answer
Speeding up spring/filled thermometers — what <em>not</em> to put in the well? To improve response speed, the clearance between a pressure spring liquid/gas expansion thermometer bulb and its thermowell is often filled with a good heat-transfer medium. Which of the following should <em>not</em> be used as the fill material?
Open
View answer
Routh–Hurwitz stability test in control engineering Which of the following statements correctly describes a limitation or capability of the Routh–Hurwitz criterion applied to a linear time-invariant system?
Open
View answer
Paramagnetism vs diamagnetism in continuous flue-gas analysis A continuous flue-gas analyzer that uses magnetism relies on paramagnetic components moving toward the strongest magnetic field, displacing diamagnetic gases. Which of the following gases is diamagnetic?
Open
View answer
Analytical instrumentation – what does a mass spectrometer analyze best? Mass spectrometry is especially suited for composition analysis and identification of which of the following?
Open
View answer
Physical systems – example exhibiting underdamped behavior Which of the following is a typical real-world example of an underdamped dynamic system?
Open
View answer
Flow measurement – identify the device that is not a differential-pressure meter Which of the following is <em>not</em> a differential-pressure (DP) type flow meter?
Open
View answer
Bolometer – working principle and purpose In basic instrumentation terms, a bolometer is best described as which of the following?
Open
View answer
Bode plots and excitation signals Bode magnitude and phase plots are generated from a system’s steady-state response to which class of input?
Open
View answer
Control systems with dead time (transportation lag): For a feedback system that contains a significant pure time delay (transportation lag), which analysis approach is generally the most reliable for assessing closed-loop stability and margins?
Open
View answer
Industrial thermocouples and protection wells: When a bare thermocouple junction is enclosed in a protective sheath (thermowell), how does the dynamic response typically change?
Open
View answer

Practice smarter