Process Control and Instrumentation Questions
Usable temperature range of copper resistance thermometers (RTDs): Select the typical operating range for a copper resistance thermometer in industrial service.
Controller terminology in PID tuning: In classical PID nomenclature, the term “reset rate” is another name for which tuning parameter or action time?
Rhodium content in Pt–Rh thermocouples: What is the normal percentage of rhodium in the platinum–rhodium element used in common high-temperature thermocouples?
Solar radiation measurement in process and environmental engineering: a pyranometer is an instrument used for measuring which component of solar irradiance on a horizontal surface?
Pressure measurement fundamentals: an aneroid barometer (without liquid) is designed to measure which kind of pressure directly?
International temperature scales and fixed points: identify the pair that does not belong to the classic list of seven fixed-point substances historically selected for calibration.
Liquid-in-glass thermometers and fluid selection: considering volumetric expansion with temperature, which of the following liquids has the smallest volumetric expansion over a typical operating range (hence enabling finer scale spacing)?
Vacuum units: in very low-pressure work, 1 micron (μ) is defined as how many millimetres of mercury (mm Hg) absolute at 0 °C?
Upper temperature range of mercury-in-glass thermometers: up to approximately what temperature (°C) can a standard pressurized mercury thermometer be used?
Application range of Bourdon tube pressure gauges: for which range are Bourdon gauges typically used most effectively (units: kg/cm²)?
Thermocouple construction basics: all thermocouples used for temperature measurement rely on dissimilar metal __________ to generate a thermoelectric voltage.
First-order plus dead time (FOPTD) system: a unity-gain process has time constant τ = 5 min. If the phase lag at excitation frequency ω = 0.2 rad/min is 60°, what is the dead time θ (minutes)?
Second-order underdamped step response: identify the single correct statement about how key response features depend on the damping ratio ζ.
In an exothermic chemical reactor under temperature control, which flow rate is most commonly selected as the manipulated variable to regulate reactor temperature while maintaining safe operation and stable conversion?
Offset in a first-order process controlled by proportional (P-only) control with gain Kc: what modification to the control strategy most effectively eliminates steady-state offset without relying on extreme gain values?
Helium constant-volume gas thermometer: select the temperature range for which this primary standard instrument is suitable in practice, given helium’s stability at very high temperatures.
Dilatometer application in measurement and materials testing: identify the physical quantity a dilatometer is designed to measure when a specimen experiences temperature changes during a controlled program.
Optical activity of a solution can be determined using a
Well-mixed tank heating/cooling model (repaired): Water enters a perfectly mixed tank at flow rate Q0 and temperature T0 and leaves at flow rate Q with exit temperature T. Heat losses are negligible. The tank volume V is constant (level control maintained). Which dynamic energy balance best describes the temperature change with time?
Which classical stability assessment explicitly uses the open-loop transfer function to determine closed-loop stability margins and encirclements?