Dimensionality check in dynamics: The unit of a system “time constant” (for first-order dynamics or analogous exponential responses) is the same as which of the following?
Meaning of pyrometry in temperature measurement: In industrial metrology, “pyrometry” refers most correctly to the measurement of temperature that is primarily of which kind?
Invar composition knowledge check (thermocouple materials): Invar is an iron–nickel alloy used in instrumentation. Approximately what percentage of nickel does invar contain?
P&ID symbology: In ISA S5.1–style instrumentation diagrams, which description best represents the symbol for a “locally mounted instrument” (i.e., field-mounted, not in a control room panel)?
Thermocouple applicability across temperature regimes: For which temperature regime(s) are thermocouples suitable in industrial measurement?
Applying manometers appropriately: Liquid column manometers are generally used to measure pressures of what approximate magnitude (gauge)?
International temperature scale segment: The platinum resistance thermometer is used as the international reference standard between which fixed points/limits?
Second-order underdamped control system: identify the correct relationship between decay ratio and overshoot, and the qualitative effect of damping coefficient on overshoot (choose the only correct statement).
Non-contact high-temperature measurement: the temperature of which of the following cannot be reliably measured directly by an optical or radiation pyrometer, and why?
Extending the upper range of a mercury-in-glass thermometer: a normal instrument reads to ~300 °C. How can the measurable range be increased to about 500 °C without changing the sensing fluid?
Frequency response terminology: the frequency at which a system attains its maximum amplitude ratio in sinusoidal steady-state is called the __________ frequency.
Laplace transform correction (Recovery applied): for the time-domain function f(t) = t^2, determine its Laplace transform.
First-order element with unity gain: when subjected to a sinusoidal input of frequency ω = 1/τ, what is the amplitude ratio (magnitude of frequency response)?
Which analytical instrument measures composition by using the change of refractive index (angle of refraction) with solution composition?
Thermocouple calibration behavior: over practical ranges, the thermal emf–temperature relationship of most industrial thermocouples is best described as
Control-system design objective: If the closed-loop response must be free from steady-state offset (zero steady-state error) and also free from sustained oscillations, which controller structure is most suitable?
Frequency-domain conversion: Which formula correctly converts an amplitude ratio (AR) into decibels (dB)?
Analytical technique scope: Flame photometry is primarily used to determine the composition of which class of species?
High-temperature measurement choice: Which instrument is not generally suitable for measuring the temperature of a red-hot object in the range of 800–1600 °C under typical industrial, non-contact conditions?
Stability margins from Bode plots: In frequency-response analysis, the gain margin is numerically equal to which of the following quantities (using amplitude ratio at the phase-crossover frequency)?