Among the listed thermocouples, identify the pair capable of measuring the highest temperatures (extreme high-temperature applications under protective atmospheres).
Analytical instrumentation application: Gas chromatography (GC) is primarily used to measure which quantity in a sample stream under appropriate calibration and detection?
Materials of construction for thermistors: identify what thermistors are typically made of, given their large negative temperature coefficient and semiconductor behavior.
Closed-loop dynamics: a unity-feedback system has an integrating process Gp(s) = 1/(2 s). The controller considered is purely integral with Gc(s) = 1/(T1 s). For a step change in set point, what qualitative response will the controlled variable exhibit?
Frequency-response fundamentals: a Bode diagram consists of which plots for a linear system's transfer function when expressed versus frequency?
For a first-order process characterized by a resistance R and a capacitance C (electrical or analogous thermal/fluid storage), what is the time constant τ expressed in terms of R and C?
Chemical process nonlinearity: choose the system that typically exhibits nonlinear dynamic behavior due to temperature–rate coupling and energy balance effects.
Radiation pyrometry: select the condition under which accurate temperature measurement performance of a radiation pyrometer is not adversely affected among the listed scenarios.
Thermocouple alloys — identify the exception: Which of the following commonly used thermocouple materials does not contain nickel in its composition?
Control systems — unit step response at t = 0⁺: For the transfer function G(s) = (s + 1) / (2s + 1), what is the initial value (at t = 0⁺) of the unit step response?
Remote indication — choose the unsuitable thermometer: Which of the following is not suitable for distant (remote) reading over lengths up to about 60 metres in industrial practice?
Open-channel metering — small channels: For measuring the liquid flow rate in a small open channel, which primary measuring device is the most appropriate?
Pressure measurement fundamentals: A barometer is an instrument that measures which kind of pressure?
Non-contact high-temperature measurement: Compared with thermocouples, which statement best characterises radiation pyrometers used in industry?
Process control concepts — spot the incorrect statement: Which of the following statements is wrong in the context of common modelling and control choices for process units?
Filled-system expansion thermometers — lowest temperature capability: Which of the following filled-system/expansion thermometers can measure to the lowest temperatures reliably?
Gas constant-volume thermometry — hydrogen range: What is the typical operating temperature range (°C) for a hydrogen gas constant-volume thermometer?
First-order systems under sinusoidal excitation: When a sinusoidal input passes through a linear first-order system, how does the output amplitude and frequency change?
Control systems – classify inputs by boundedness From the following standard test inputs (given by their Laplace transforms), identify which input is unbounded as time increases: 1, 1/S, 1/S^2, and 1/(S^2 + 1).
Thermometry basics – which temperature scale assigns 0° to the ice point and 80° to the steam point at standard pressure?