Process Control and Instrumentation Questions
High-temperature measurement: a radiation pyrometer operates fundamentally according to which physical law relating radiated energy to temperature?
Electromagnetic flow measurement: which statements about a magnetic flowmeter are correct?
Liquid-level dynamics: for a single well-mixed tank with linear outlet resistance, what is the transfer function from inlet flow rate to liquid level?
Thermometry principles: which thermometer operates on volumetric expansion of a liquid?
Control systems — Nichols chart interpretation In classical frequency-response design, the Nichols chart plots what relationship to help map open-loop data to closed-loop performance?
Analytical instrumentation — suitable use of mass spectrometry For which sample type is mass spectrometry classically employed to perform detailed compositional (especially isotopic) analysis in process and laboratory settings?
Thermocouple wiring — insulation limits What is the maximum recommended service temperature for fibre-glass insulation on thermocouple extension/compensation wires in typical industrial use?
Flow measurement — principle of a rotameter A rotameter (variable area flowmeter) indicates flow rate primarily based on which operating principle?
In applied thermodynamics and HVAC testing, humidity of ambient air is commonly determined using which field instrument that compares dry-bulb and wet-bulb temperatures while being whirled through the air?
Analytical methods for sucrose and other optically active sugars: the concentration of a sugar solution is most directly determined using which optical technique that measures the angle of rotation of plane-polarized light?
Gas constant-volume thermometry with nitrogen: a nitrogen gas constant-volume thermometer is particularly suitable for measuring temperatures in which range relative to 100 °C?
Electrical resistance strain gauge principle: when a fine conductor in a bonded strain gauge is elastically stretched, its length increases and diameter decreases. The combined dimensional changes result in what net change in electrical resistance?
Basic density testing: which of the following devices cannot be used to measure the specific gravity (relative density) of a liquid sample in a lab or field setting?
Frequency response of a first-order linear system: the steady-state phase shift between sinusoidal input and output varies between which lower and upper limits (in radians) as excitation frequency goes from very low to very high?
High-temperature measurement capability: which of the following instruments cannot measure a temperature as high as about 1600 °C under normal usage?
Dynamic measurement quality: the degree to which an instrument reproduces changes in the measured variable with no dynamic distortion (i.e., the output waveform is a faithful copy of the input) is called its what?
Controller design basics: for a proportional–derivative (P–D) controller, what is the standard transfer function form in the Laplace domain?
Open-channel discharge measurement: the volumetric flow rate of a river (free-surface flow) is most appropriately measured using which hydraulic structure or device?
In instrumentation and control engineering, the term ‘‘dead zone’’ refers to the input–output insensitivity of an indicating or recording device. Which definition best captures this concept for a measurement instrument (do not confuse with time constant or pure transportation lag)?
Thermocouple selection for high temperatures: which pair is suitable for measuring about 1400°C in industrial practice, considering stability and usable range?