Process Control and Instrumentation Questions
Diaphragm pressure sensor mechanics – dependence on diameter For a thin, circular diaphragm used as a pressure-sensing element (with material, thickness, corrugation design, and clamping held constant), the central deflection under uniform pressure varies with the diaphragm diameter d according to which proportionality?
Stalagmometer (drop count method) A stalagmometer is primarily used to measure which property of a liquid by counting drops formed at a capillary tip?
Second-order system – phase lag in frequency response For a standard underdamped second-order system excited by a sinusoidal input, how does the phase lag of the output behave as frequency increases?
Zirconia oxygen probe in combustion monitoring A zirconia (zirconium dioxide, YSZ) probe installed in flue ducts is used to measure which flue-gas component in percent?
Flow metering – device capable of measuring the largest flow rate Among the listed primary elements/meters, which is generally used to measure the largest flow rates in practice?
Polarography (dropping mercury electrode) – application domain Polarograph-based analysis is primarily intended for which kind of samples or systems?
Root locus fundamentals – definition of a pole In the context of the root locus method, a pole of a transfer function G(s) is the value of s for which G(s) tends to which limiting value?
Thermocouples – order of magnitude of generated EMF The electromotive force (EMF) produced by standard thermocouple junctions for practical temperature differences is typically of what order of magnitude?
Flow metering classification in process plants: Among the following instruments, which one operates as an area meter (i.e., variable-area type) for measuring volumetric flow rate?
Comparative accuracy of temperature instruments: Among these temperature-measuring devices used in process engineering, which typically provides the lowest measurement accuracy under normal plant conditions?
Gas analysis detector principle: A thermal conductivity cell (katharometer) is commonly used as the primary sensing element in which type of gas analyser for process streams?
Measuring small furnace draught with an inclined manometer: For accurate measurement of very low negative pressures (draught) in furnaces using an inclined tube manometer, which manometric liquid is most commonly used?
Trace moisture in organic systems: Which analytical method is suitable for detecting a small amount of water present in predominantly organic liquids or solutions?
Recovering the intended model class (dead time vs dynamic order): Assume the open-loop transfer function shown in the original stem was a pure transport delay of the form G(s) = exp(-θs). This representation corresponds to which type of system description?
Static vs dynamic characteristics in instrumentation: Which of the following is classified as a static characteristic of an instrument (i.e., observed under steady or very slowly varying conditions)?
Solar radiation instruments in energy and environmental engineering: A pyrheliometer is specifically designed to measure which component of solar radiation at the Earth’s surface?
What does a simple pitot tube measure in a flowing fluid? Choose the most precise statement about the quantity indicated by a basic L-shaped pitot tube inserted into a pipe or duct stream.
Correcting the stem per Recovery-First Policy (iron–constantan thermocouple): The stated usable range is 0 to 870 °C for an iron–constantan (Type J) thermocouple. It cannot be reliably used at sub-zero temperatures mainly because, at lower temperature, which issues arise?
Flow measurement for corrosive or hostile process liquids (strong acids and alkalis): which instrument is most suitable for accurate, reliable flow rate indication without intrusive pressure drop or corrosion issues?
Level measurement in a pressurized vessel: which device directly determines the liquid level while cancelling the effect of vessel pressure?