Process Control and Instrumentation Questions

Practice Process Control and Instrumentation MCQs with answers and explanations. Page 7 of 17.

Category
Chemical Engineering
Topic
Process Control and Instrumentation
Page
7 / 17
Mode
Practice

Questions

Open any question to view the answer and explanation.

Steady-state offset among classical controllers: For a unit-step load/change on a stable process, which controller structure tends to have the largest steady-state offset (residual error)?
Open
View answer
Level measurement for cryogenic liquid in a pressurised tank: Liquid argon level in a pressurised storage tank (about 3 kg/cm²) should be measured using which primary method?
Open
View answer
Optical radiation pyrometer lower limit: What is the typical starting (lower) temperature for reliable measurement by an optical radiation pyrometer in industry?
Open
View answer
Why magnetic flowmeters avoid hydrocarbons: Magnetic (electromagnetic) flowmeters are generally not used for measuring hydrocarbon flow/velocity because hydrocarbons typically have which limiting property?
Open
View answer
Turbine flowmeter application spectrum: Turbine meters are especially suitable for which of the following application domains?
Open
View answer
PI control (proportional + integral) in process control When integral (I) action is added to proportional (P) control in a feedback loop, which key performance outcome is enabled under steady disturbances and setpoint changes?
Open
View answer
First-order plus time delay (FOPDT) model Select the correct transfer function form for a first-order process with pure time delay (dead time) θ, process gain K, and time constant τ.
Open
View answer
Open-channel discharge measurement Liquid discharge from a tank or reservoir (free surface) cannot be measured using which of the following primary devices?
Open
View answer
Frequency response signature – constant magnitude, linear phase lag A dynamic element exhibits unit (constant) magnitude at all frequencies and a negative phase that increases linearly in absolute value with frequency. Which transfer function matches this behavior?
Open
View answer
Barometry and pressure types A mercury barometer is designed to measure which type of pressure directly?
Open
View answer
Principle of polarography – which sample state is analyzed? Polarography (dropping-mercury-electrode voltammetry) is primarily used to analyze which type of samples?
Open
View answer
Measuring sub-zero (°C) temperatures in industry Which instrument type is most commonly used for accurate and reliable industrial temperature measurement below 0 °C?
Open
View answer
Mechanical vs manometric pressure elements Which of the following is <em>not</em> a mechanical elastic pressure sensing element?
Open
View answer
Vacuum measurement – Pirani gauge application range A Pirani gauge is typically used to measure which pressure regime?
Open
View answer
Psychrometry and humidity measurement in process engineering: What parameter does a psychrometer directly determine when used with gas streams in drying or air-conditioning operations?
Open
View answer
Characteristic equation in feedback control: For a closed-loop transfer function written as G1 / (1 + G2), the characteristic equation is 1 + G2 = 0. What does this imply about dependence, stability assessment, and applicability to set-point vs load changes?
Open
View answer
Frequency response of a first-order system under sinusoidal forcing: For a first-order system subjected to a sinusoidal input, what is the ratio of output amplitude to input amplitude (the sinusoidal steady-state gain)?
Open
View answer
Alphatron low-pressure measurement range: The Alphatron instrument (an ionisation-type vacuum gauge) measures absolute pressure most effectively in which microns of mercury range?
Open
View answer
Assessing stability from transfer-function denominators: Which of the following single-input single-output systems is (asymptotically) stable based on its denominator polynomial?
Open
View answer
Measuring ~2000°C on incandescent mantles: Which instrument is most appropriate to measure the very high temperature (around 2000°C) of an incandescent gas mantle or filament?
Open
View answer

Practice smarter

Solve a few questions daily and revisit weak topics regularly to improve accuracy.