Multivibrators — Astable vs. Monostable What is the key operational difference between an astable multivibrator and a monostable multivibrator?
-
AThe astable is free running.
-
BThe astable needs to be clocked.
-
CThe monostable is free running.
-
Dnone of the above
Answer
Correct Answer: The astable is free running.
Explanation
Introduction / Context:Multivibrators are timing and waveform generation circuits. Understanding their operating modes is fundamental to digital electronics and timing design.
Given Data / Assumptions:
- Compare astable and monostable configurations.
- Assume standard RC timing and comparator thresholds for IC 555 or logic gate equivalents.
Concept / Approach:An astable multivibrator oscillates continuously without external triggering, generating a periodic waveform. A monostable has one stable state and produces a single pulse when externally triggered, then returns to its stable state.
Step-by-Step Solution:1) Astable: no stable states; capacitor repeatedly charges and discharges, causing regular toggling.2) Monostable: one stable state; a trigger forces a temporary quasi stable state for a time T = k * R * C, then it returns to the stable state.3) Therefore, the distinguishing feature is free running behavior versus trigger dependent single pulse.
Verification / Alternative check:Standard texts classify astable as a free running oscillator and monostable as a one shot pulse generator.
Why Other Options Are Wrong:
- The astable needs to be clocked.: Incorrect; it self oscillates.
- The monostable is free running.: Incorrect; it requires a trigger to start the pulse.
- none of the above: Not true since option stating astable is free running is correct.
Common Pitfalls:Assuming both require triggers; confusing monostable with bistable flip flops.
Final Answer:The astable is free running.