Laser printer diagnostics: A laser printer outputs a completely black page. Which cause is most likely?
-
Amalfunctioning imaging laser
-
Blow level in the toner cartridge
-
Cno power to transfer corona
-
Dno power to the primary corona
-
ENone of the above
Answer
Correct Answer: no power to the primary corona
Explanation
Introduction / Context:In electrophotographic (laser) printing, several charging stages prepare and develop the image on the drum before transfer and fusing. Recognizing symptom-to-stage relationships speeds troubleshooting and parts replacement.
Given Data / Assumptions:
- Total page is uniformly black.
- Printer otherwise feeds and fuses normally.
- Focus on the most probable single-point failure.
Concept / Approach:The primary charge (corona or charge roller) applies a uniform charge to the drum. The laser then selectively discharges areas to form the latent image. If the primary charging stage fails (no power to the primary corona/roller), the drum is not correctly precharged and tends to attract toner across the entire surface during development, producing a solid black page. By contrast, a failed imaging laser usually yields blank pages (no discharging, toner repelled), not black ones. Transfer issues affect how the image gets onto paper, not whether it is all black.
Step-by-Step Solution:
Identify the uniformity of the fault: full black coverage implies charging/develop bias failure.Map to subsystem: primary charge stage not working.Conclude: No power to primary corona is the most likely cause.Verification / Alternative check:Swap in a known-good charge assembly or perform engine test pages; service manuals list this symptom for primary charge failures.
Why Other Options Are Wrong:Imaging laser malfunction tends to produce blank (white) pages. Low toner reduces density, not creates black pages. Transfer corona failure leaves image on drum or causes faint prints, not a solid black page.
Common Pitfalls:Replacing toner unnecessarily or suspecting the formatter when the electrophotographic core is at fault.
Final Answer:no power to the primary corona