ADC methods — which conversion approach has a fixed conversion time? Consider common analog-to-digital converter (ADC) architectures used in embedded systems. Identify the method whose conversion time does not depend on the analog input amplitude and remains essentially constant from conversion to conversion.
-
ASingle-slope analog-to-digital converter
-
BDual-slope analog-to-digital converter
-
CDigital-ramp analog-to-digital converter
-
DSuccessive-approximation analog-to-digital converter
-
EFlash (parallel-comparator) analog-to-digital converter
Answer
Correct Answer: Successive-approximation analog-to-digital converter
Explanation
Introduction / Context:Different analog-to-digital converter (ADC) architectures trade off speed, accuracy, cost, and complexity. A key specification is conversion time. Some ADCs take a constant time regardless of the input level, while others have input-dependent conversion latency. Knowing which family offers fixed conversion time is essential for real-time sampling and deterministic control loops.
Given Data / Assumptions:
- The question compares standard ADC architectures: single-slope, dual-slope, digital ramp (counter-type), successive-approximation (SAR), and implicitly flash.
- “Fixed conversion time” means the number of decision steps is input-independent.
- We assume ideal implementations without pipeline or interface wait states.
Concept / Approach:A SAR ADC performs a binary search of the input using an internal DAC and comparator. For an N-bit SAR, exactly N comparison steps are required, so the conversion time is basically N clock cycles (plus small overhead) and is independent of the input voltage. In contrast, a digital-ramp (counter-type) ADC counts up until the DAC matches the input, so time depends on the code value. Single/dual-slope integrate for predetermined intervals but include portions that depend on input. Flash is also fixed time but is typically considered a separate extreme (very fast, many comparators). Among the listed options, SAR is the general fixed-time, mainstream choice.
Step-by-Step Solution:
Identify architecture with fixed decision count → SAR does binary search in N steps.Single-/dual-slope rely on integration/discharge intervals tied to input or timing windows.Digital ramp counts up to the input code; time varies with amplitude.Therefore, the fixed-time method here is SAR.Verification / Alternative check:Data sheets of popular 8–16 bit SAR ADCs specify conversion time as a fixed multiple of the internal clock (for example, N + 2 cycles), independent of input. Counter-type ADCs show worst-case varying up to full-scale counts.
Why Other Options Are Wrong:
- Single-slope: discharge/charge timing relates to input, not fixed to a set count.
- Dual-slope: the rundown time depends on input, even though it averages noise.
- Digital ramp: count time scales with input code value.
- Flash: fixed time but not provided as the original correct choice in many curricula; SAR is the standard fixed-time answer here.
Common Pitfalls:
- Assuming dual-slope is fixed-time; only the integrate window is fixed, not the full conversion duration.
Final Answer:Successive-approximation analog-to-digital converter