Tacking rivets in tension members – maximum spacing (pitch in line) In a tension member, tacking rivets are provided at a pitch in line not exceeding:

Difficulty: Easy

Correct Answer: 100 cm

Explanation:


Introduction / Context:
Tacking rivets (or bolts) in tension members prevent local separation of built-up components and maintain alignment. Codes limit their spacing to ensure adequate stitching even when the primary connectors are widely spaced.



Given Data / Assumptions:

  • Tension member composed of multiple components (e.g., double angles or plates).
  • Looking for maximum allowed pitch in line for tacking rivets.



Concept / Approach:
For tension members, the usual maximum spacing limit is about 1.0 m along the member line (i.e., 100 cm). This differs from compression members, for which limits are generally smaller to control buckling of components.



Step-by-Step Solution:
Identify member type → tension.Apply spacing rule → pitch ≤ 100 cm.Select 100 cm from the options.



Verification / Alternative check:
Handbook detailing tables consistently list a 1 m maximum pitch for tacking fasteners in tension members.



Why Other Options Are Wrong:

  • 25, 50, 75 cm: more conservative than required by common guidance.



Common Pitfalls:
Applying compression-member stitching limits to tension members; compression requires tighter stitching due to local buckling risk.



Final Answer:
100 cm

More Questions from Steel Structure Design

Discussion & Comments

No comments yet. Be the first to comment!
Join Discussion