Riveted joints – Crushing (bearing) resistance per pitch length For a single rivet in a lap or butt joint, the pull required to crush the rivet per pitch length is given by which expression? (Use d = rivet diameter, t = plate thickness, σc = allowable crushing/bearing stress)
-
Ap * t * σt
-
Bd * t * σc
-
Cπ/4 * d^2 * σt
-
Dπ/4 * d^2 * σc
-
Ep * d * σc
Answer
Correct Answer: d * t * σc
Explanation
Introduction / Context:Designing riveted joints requires checking multiple failure modes per pitch: tearing of plate, shearing of rivet, and crushing (bearing) of material. The crushing check uses the projected bearing area and the allowable bearing stress.
Given Data / Assumptions:
- Single rivet considered per pitch length.
- d = rivet diameter; t = plate thickness.
- σc = allowable bearing (crushing) stress of the weaker bearing pair (plate or rivet).
Concept / Approach:The bearing resistance equals allowable bearing stress multiplied by the projected contact area between rivet and plate. For a round rivet bearing on plate thickness t, projected area = d * t. Thus the force to cause bearing failure is d * t * σc.
Step-by-Step Solution:Projected bearing area A_b = contact width d * thickness t.Allowable bearing stress = σc.Crushing (bearing) resistance per rivet = A_b * σc = d * t * σc.Compare with other modes to size the joint based on the least capacity.
Verification / Alternative check:Dimension check: N = (m) * (m) * (N/m^2) → N, consistent with force. Common textbooks derive the same expression for bearing strength.
Why Other Options Are Wrong:(a) uses pitch p and tensile stress σt, which relates to plate tearing not bearing. (c) and (d) use circular area (π/4 * d^2) relevant to shearing or tensile area, not bearing. (e) introduces an extra p, not part of bearing area.
Common Pitfalls:Confusing bearing strength with rivet shear or plate tearing; using net-section area instead of projected contact area.
Final Answer:d * t * σc