Difficulty: Easy
Correct Answer: both current and voltage derating
Explanation:
Introduction / Context:
To achieve higher system ratings, SCRs are often connected in series (for voltage) and in parallel (for current). Due to inevitable parameter tolerances and dynamic effects, equal sharing is imperfect, so prudent derating is applied in design.
Given Data / Assumptions:
Concept / Approach:
In series connection, one device may see more voltage during transients → voltage derating. In parallel connection, one device may carry more current due to lower dynamic resistance or temperature effects → current derating. Therefore, both current and voltage derating are typically specified when combining devices for higher ratings.
Step-by-Step Solution:
Verification / Alternative check:
Manufacturer application notes prescribe derating factors and balancing networks for both series and parallel configurations.
Why Other Options Are Wrong:
Common Pitfalls:
Assuming perfect sharing from idealized SPICE models; practical builds require margins and balancing networks.
Final Answer:
both current and voltage derating
Discussion & Comments