Difficulty: Easy
Correct Answer: 0.33 d
Explanation:
Introduction / Context:
Vertical stiffeners prevent web buckling and help distribute concentrated loads in plate girders. Codes and handbooks prescribe limits on the maximum and minimum spacing, often expressed as fractions of the clear web depth d (between inner faces of flange angles) when horizontal stiffeners are absent.
Given Data / Assumptions:
Concept / Approach:
Too-close stiffeners are uneconomical and can cause fabrication congestion, while too-wide spacing risks web instability. Traditional guidance sets a lower bound around one-third of the clear depth, i.e., ≥ 0.33 d, to ensure a rational panel aspect ratio and practical detailing.
Step-by-Step Solution:
Identify the reference dimension: d (clear depth).Apply the empirical minimum spacing criterion: s_min ≈ 0.33 d.Choose the listed value 0.33 d.
Verification / Alternative check:
Sample designs using typical web slenderness limits show vertical panel widths between about 0.33 d and 1.5 d depending on shear demand and web thickness, consistent with the stated minimum spacing.
Why Other Options Are Wrong:
Common Pitfalls:
Final Answer:
0.33 d