Rigid-tank acceleration (non-inertial hydrostatics): A 4 m × 3 m × 2 m closed tank filled with oil (specific gravity = 0.83) is moved vertically with acceleration a = g/2. What is the ratio of bottom pressures when moving upward versus downward?

Difficulty: Medium

Correct Answer: 3

Explanation:


Introduction / Context:

This problem checks understanding of apparent gravity in accelerating reference frames. A rigid, completely filled tank experiencing vertical acceleration shows an effective hydrostatic gradient based on g_eff = g ± a, which directly scales pressure at a given depth.


Given Data / Assumptions:

  • Tank dimensions: 4 m × 3 m × 2 m (depth relevant, but ratio cancels).
  • Fluid: oil with specific gravity 0.83 (density scales pressure but cancels in the ratio).
  • Vertical acceleration magnitude: a = g/2.
  • Bottom pressure considered at the same physical depth during up and down motions.


Concept / Approach:

In a non-inertial frame accelerating vertically, the pressure variation remains hydrostatic but with effective gravity g_eff. When the tank accelerates upward, g_eff = g + a; when accelerating downward, g_eff = g − a. The absolute bottom pressure (for the same free surface reference) scales in proportion to g_eff.


Step-by-Step Solution:

Upward motion: g_eff(up) = g + a = g + g/2 = 3g/2.Downward motion: g_eff(down) = g − a = g − g/2 = g/2.Bottom pressure ∝ ρ * g_eff * depth. Ratio p_up / p_down = (3g/2) / (g/2) = 3.


Verification / Alternative check:

Since density ρ and depth h are identical in both cases, they cancel in the ratio, leaving only g_eff terms; hence the numerical result is independent of SG = 0.83 and the tank dimensions.


Why Other Options Are Wrong:

  • 2 results from mistakenly using a = g/1 instead of g/2.
  • 1/2 and 1/3 invert the intended order (they would be p_down/p_up or use wrong arithmetic).
  • 1 would imply no effect of acceleration, which is untrue.


Common Pitfalls:

  • Using g instead of g ± a for accelerating containers.
  • Trying to include the plan dimensions or density in the final ratio (they cancel).


Final Answer:

3

More Questions from Hydraulics