Manometer capillarity avoidance – minimum tube diameter To minimize meniscus curvature and avoid significant capillary correction in pressure measurement, the manometer tube should have at least what internal diameter?
-
A2 mm
-
B4 mm
-
C6 mm
-
D8 mm
-
E10 mm
Answer
Correct Answer: 6 mm
Explanation
Introduction / Context:Capillary rise or depression in narrow tubes distorts liquid column readings in manometers, especially with water and clean glass. Selecting a sufficiently large internal diameter helps keep errors negligible without complex meniscus corrections.
Given Data / Assumptions:
- Clean glass tube and water (or similar wetting fluid).
- Room temperature conditions where surface tension is typical.
- Objective: keep capillary rise/depression small relative to resolution.
Concept / Approach:
Capillary height is inversely proportional to tube radius: h_c ≈ 2 σ cos θ / (ρ g r). Increasing diameter (2r) reduces h_c rapidly. Practical laboratory and field practice often adopts ≥ 6 mm I.D. to make capillary corrections negligible for routine measurements.
Step-by-Step Solution:
Recognize h_c ∝ 1/r; doubling radius halves the capillary effect.Common guidance: for water–glass, I.D. ≥ 6 mm limits h_c to a few tenths of a millimeter, typically within reading uncertainty.Hence, select at least 6 mm internal diameter.Verification / Alternative check:
Using typical values (σ ≈ 0.072 N/m, θ ≈ 0°, ρ ≈ 1000 kg/m^3) gives small h_c when r ≥ 3 mm. Many textbooks recommend 6–10 mm I.D.; 6 mm is the common minimum.
Why Other Options Are Wrong:
(a) and (b) are too small; capillarity is significant. (d) and (e) are acceptable but unnecessarily large relative to the “minimum” asked; the conventional cut-off is about 6 mm.
Common Pitfalls:
Ignoring contact-angle effects with dirty or coated tubes; forgetting that mercury behaves oppositely (depression instead of rise). Always read at consistent meniscus position if correction is unavoidable.
Final Answer:
6 mm