Boiler heat-recovery devices: location of the air preheater Identify where an air preheater is typically installed in the boiler flue-gas path relative to the economiser and chimney. Choose the correct location.

Mechanical Engineering Steam Boilers and Engines Difficulty: Easy
Choose an option
  • A
    Before the economiser (hotter gas goes first to air preheater)
  • B
    Before the superheater
  • C
    Between the economiser and the chimney
  • D
    None of these

Answer

Correct Answer: Between the economiser and the chimney

Explanation

Typical arrangement

  • Superheater → Economiser → Air preheater → Chimney (gas progressively cools).

Reason

Air preheaters recover the lowest grade of heat (lowest gas temperatures) to preheat combustion air before it enters the furnace, so they are usually placed just before the chimney, downstream of the economiser.