Boilers: identify the type when water circulation is driven by a centrifugal pump Circulation of water in the boiler is provided by a mechanical pump rather than by density difference or natural convection. Choose the correct boiler classification.
Mechanical Engineering
Steam Boilers and Engines
Difficulty: Easy
Choose an option
-
AInternally fired boiler
-
BExternally fired boiler
-
CNatural circulation boiler
-
DForced circulation boiler
Answer
Correct Answer: Forced circulation boiler
Explanation
ConceptWhen circulation is produced by a pump, the unit is termed a forced circulation boiler. Natural circulation relies on density difference between hot and cold water; forced systems use a centrifugal (circulating) pump to move water through the evaporator, risers, and downcomers.
Why the others are wrongInternally/externally fired classify furnace position, not circulation method. Natural circulation is explicitly without a pump.
Final AnswerForced circulation boiler