Difficulty: Easy
Correct Answer: equal
Explanation:
Introduction / Context:AC voltage regulators that use two antiparallel thyristors (or a triac) control the RMS output by delaying firing in each half-cycle. A key practical requirement is to avoid any DC component in the load current, which can saturate transformers and cause torque pulsations in motors.
Given Data / Assumptions:
Concept / Approach:
A DC component arises when the conduction in the positive half-cycle is not symmetrically matched by the conduction in the negative half-cycle. Equal firing angles (symmetrical control) ensure that the average of the output over a full period is zero, preventing DC magnetization and minimizing even-harmonic content.
Step-by-Step Solution:
For symmetrical control: set α+ = α- = α.Positive half-cycle conduction mirrors negative half-cycle conduction in time and amplitude.The average (DC) value over one period cancels to approximately zero for resistive or typical AC loads.This also reduces even harmonics and prevents transformer core saturation.Verification / Alternative check:
Using Fourier analysis, asymmetrical gating introduces even harmonics and a nonzero average value. Symmetrical gating (equal α) removes these issues in standard applications.
Why Other Options Are Wrong:
Common Pitfalls:
Final Answer:
equal