Difficulty: Easy
Correct Answer: L = l/2
Explanation:
Introduction / Context:End restraint increases the critical buckling load by reducing the effective length of a column. Knowing the correct effective length for each end condition is vital for safe, economical column design.
Given Data / Assumptions:
Concept / Approach:The Euler critical load uses effective length L_e = K * l, where K depends on end conditions. For both ends fixed, K = 0.5. Thus L_e = 0.5 * l. The reduced length raises the critical load to four times that of a pinned–pinned column of the same actual length.
Step-by-Step Solution:
End condition: fixed–fixed ⇒ K = 0.5Effective length: L = K * l = 0.5 * lEuler load: P_cr = pi^2 * E * I / L^2 = pi^2 * E * I / (0.5 l)^2 = 4 * (pi^2 E I / l^2)Verification / Alternative check:From buckling mode shapes, a fixed–fixed column has half-wavelength equal to l, implying effective pinned length of l/2 for the same mode.
Why Other Options Are Wrong:L = l corresponds to pinned–pinned; L = 2l to fixed–free (cantilever); fractional roots do not match standard K-factors.
Common Pitfalls:Confusing K-factors among end conditions; misapplying effective length in slenderness ratio and Euler load calculations.
Final Answer:
L = l/2