Difficulty: Easy
Correct Answer: 8 bar
Explanation:
Introduction / Context:Approximate operating pressures help technicians and students check gauges, anticipate component ratings, and identify faults. R-12 (legacy refrigerant) typically runs at moderate condenser pressures for comfort or commercial refrigeration conditions.
Given Data / Assumptions:
Concept / Approach:Condenser pressure corresponds to saturation pressure at typical condensing temperatures (say 35–45°C). For R-12 in this range, saturation pressures are commonly around 7–9 bar absolute. Evaporator pressures for above-zero evaporating temperatures are much lower (often 2–3 bar range), but the question focuses on condenser pressure.
Step-by-Step Solution:
Select a typical condensing temperature, e.g., 40°C.Read corresponding R-12 saturation pressure from tables: roughly ~8 bar abs.Compare options; 8 bar best matches normal condenser operation.Therefore, choose 8 bar as a representative value.Verification / Alternative check:Manufacturer pressure–temperature charts for R-12 corroborate that around 40°C the pressure is approximately 8 bar absolute.
Why Other Options Are Wrong:
2 bar: more typical of evaporator side at mild evaporating temperatures.15 or 30 bar: far above standard R-12 condenser pressures; these are more aligned with high-pressure refrigerants or transcritical CO2 systems.0.8 bar: vacuum operation is not a normal condenser condition.
Common Pitfalls:Confusing gauge with absolute pressure and forgetting temperature dependence; always cross-check with actual ambient and heat-rejection mode.
Final Answer:
8 bar