A magnetron requires an externally applied magnetic field with flux lines oriented parallel to the cathode axis. Is this statement correct?
-
ATrue
-
BFalse
-
COnly true at very low frequencies
-
DOnly true for reflex klystrons, not magnetrons
-
ETrue only when operated in vacuum below 10^-6 torr
Answer
Correct Answer: True
Explanation
Introduction:Magnetrons are crossed-field microwave devices. They use an electric field (radial) and a magnetic field (axial) to control electron motion and generate microwave oscillations. This item checks basic device-physics orientation.
Given Data / Assumptions:
- Cylindrical magnetron with central cathode and surrounding anode cavities.
- Static magnetic field applied externally.
- Vacuum conditions typical for microwave tubes.
Concept / Approach:
In a magnetron, the DC magnetic field is applied along the axis of the cathode (axial direction), while the DC electric field is primarily radial. The crossed E and B fields cause electrons to follow complex cycloidal paths, enabling interaction with RF cavity fields.
Step-by-Step Solution:
1) Identify field geometry: E field radial; B field axial (parallel to cathode axis).2) Recognize that this orientation is essential for crossed-field operation.3) Therefore, the statement regarding flux lines parallel to the cathode axis is correct.Verification / Alternative check:
Standard magnetron diagrams show solenoids or permanent magnets arranged to produce axial magnetic flux through the interaction space.
Why Other Options Are Wrong:
- False/conditional options contradict the fundamental crossed-field design.
- Reflex klystrons are different devices; the statement pertains to magnetrons specifically.
Common Pitfalls:
Confusing magnetron geometry with klystron or TWT structures, where fields and interaction mechanisms differ.
Final Answer:
True