R.C.C. slab detailing: For a slab with main reinforcement diameter 16 mm, select the minimum nominal clear cover to main bars as per common building practice.

Civil Engineering RCC Structures Design Difficulty: Easy
Choose an option
  • A
    12 mm
  • B
    13 mm
  • C
    14 mm
  • D
    15 mm
  • E
    16 mm

Answer

Correct Answer: 16 mm

Explanation

Introduction / Context:Clear cover in slabs protects steel from corrosion and fire and ensures proper bond. Many design practices (e.g., IS 456 guidance) adopt a minimum nominal cover of 15 mm or the bar diameter, whichever is greater, for mild exposure slabs.

Given Data / Assumptions:

  • Main bar diameter = 16 mm.
  • Slab in typical building exposure (not aggressive).
  • Adopt rule: cover = max(15 mm, bar diameter).

Concept / Approach:

Choose the higher of 15 mm and 16 mm to satisfy durability and cover tolerances in slabs.

Step-by-Step Solution:

Compute max(15, 16) = 16 mm.

Verification / Alternative check:

If exposure is severe, higher cover may be required; for normal exposure, 16 mm satisfies the common minimum requirement.

Why Other Options Are Wrong:

12–15 mm are less than the bar diameter; they do not satisfy the max(15 mm, bar dia) rule for a 16 mm bar.

Common Pitfalls:

Confusing slab cover with beam cover; ignoring exposure class adjustments.

Final Answer:

16 mm