Safe RF power measurement chain for a 2 kW TWT amplifier — choose correct connection order Components available: (1) TWT amplifier (2 kW output), (2) Low-pass/High-pass filter, (3) Low-power 20 dB attenuator, (4) 40 dB directional coupler with matched load on the through line, (5) Power meter. What is the correct sequence from source to meter?

Electronics and Communication Engineering Microwave Communication Difficulty: Medium
Choose an option
  • A
    1, 4, 2, 3, 5
  • B
    1, 3, 4, 2, 5
  • C
    1, 2, 4, 3, 5
  • D
    1, 4, 3, 2, 5

Answer

Correct Answer: 1, 2, 4, 3, 5

Explanation

Introduction / Context:Measuring the output power of a high-power traveling-wave tube (TWT) amplifier requires a chain that both protects low-power instruments and provides a representative sample of the fundamental signal. The right order prevents damage and ensures accuracy.

Given Data / Assumptions:

  • TWT output power ≈ 2 kW (dangerous for small components).
  • Available parts: filter, 40 dB coupler, 20 dB attenuator, power meter.
  • Directional coupler is assumed to be high-power rated on the main line.

Concept / Approach:First, place the harmonic-conditioning filter directly after the TWT so the sampled signal represents the fundamental and to keep out-of-band energy from the measurement path. Next, use the high-power directional coupler on the main line; its coupled port extracts a small, known fraction (e.g., −40 dB) of the forward power. Then, because even the coupled power from 2 kW can still be substantial, insert a low-power 20 dB attenuator in the sample path before feeding the power meter. Finally, terminate the through line properly with the matched load or the system under test.

Step-by-Step Solution:

1) 1 → 2: TWT → Filter to clean harmonics at the source.2) 2 → 4: Filter → Directional coupler on the high-power through path.3) Coupled port → 3: Add 20 dB attenuator to further reduce level.4) 3 → 5: Feed the power meter safely.

Verification / Alternative check:With 2 kW (≈ 63 dBm), a −40 dB coupler gives ~23 dBm at the coupled port; adding −20 dB attenuation gives ~3 dBm to the meter, well within many sensors’ ranges.

Why Other Options Are Wrong:

  • A/D: Sampling before filtering yields a measurement polluted by harmonics and may stress the coupler differently.
  • B: Placing a low-power attenuator directly after a 2 kW TWT risks immediate damage.

Common Pitfalls:Connecting the low-power attenuator on the main line; omitting the filter so the meter over-reads due to harmonics.

Final Answer:1, 2, 4, 3, 5