Curioustab
Aptitude
General Knowledge
Verbal Reasoning
Computer Science
Interview
Take Free Test
Aptitude
General Knowledge
Verbal Reasoning
Computer Science
Interview
Take Free Test
Home
»
Civil Engineering
»
Structural Design Specifications
The concrete is deemed not to comply with the strength requirements if the strength is less than the greater of
characteristic strength minus 1.35 times the standard deviation
0.8 times the characteristic strength
the average strength of all the samples is less than the characteristic strength plus times the standard deviation.
all the above.
Correct Answer:
all the above.
← Previous Question
Next Question→
More Questions from
Structural Design Specifications
For continuous reinforced concrete beams under typical loading, the distance between adjacent points of contraflexure (zero bending moment) within a span is approximately what fraction of the effective span l?
For axially loaded steel columns subjected only to dead load and superimposed (sustained) service loads, what is the maximum permissible slenderness ratio?
For concrete subjected to sustained loads, the creep coefficient (ratio of ultimate creep strain to initial elastic strain) depends on the age at loading. Identify the correct typical values for loading ages of 7 days, 28 days, and 365 days.
Serviceability limit state: the maximum vertical deflection of a structural member should not normally exceed the lesser of span/350 or which fixed limit (in millimetres)?
In steel plate girder design, for webs without horizontal stiffeners that use tongue plates, the effective web depth 'd' is taken as the lesser of: (i) the clear depth between flanges minus the total depth of the tongue plates, and (ii) the clear depth between flanges minus [multiple] times the sum of tongue-plate thicknesses. Which multiple is correct?
In reinforced concrete beam design, the maximum area of compression reinforcement permitted in a rectangular section of size B Ă— D is limited to what fraction of the gross area BD?
Select the correct comprehensive statements for reinforced concrete columns regarding steel percentage, minimum number of longitudinal bars, helical reinforcement, and the pedestal definition based on effective length.
In the detailing of plate girder stiffeners, the maximum permissible outstand (projection) of a flat stiffener leg in compression should not exceed which multiple of its thickness t?
For battened compression members (battened struts), by what percentage is the effective length customarily increased to account for shear deformation and additional flexibility?
In transformed section analysis for reinforced concrete, the area considered in compression equals the concrete area in compression plus the reinforcement area converted using the modular ratio. What is this combined area called?
Discussion & Comments
No comments yet. Be the first to comment!
Posting…
Name
Comment
Post Comment
Join Discussion
Discussion & Comments