Workability limits under vibration: when compacting concrete using a mechanical vibrator, the slump value should not exceed which limit for quality placement?
Civil Engineering
Concrete Technology
Difficulty: Easy
Choose an option
-
A2.5 cm
-
B5.0 cm
-
C7.5 cm
-
D10 cm
-
E15 cm
Answer
Correct Answer: 7.5 cm
Explanation
Introduction / Context:Vibration greatly assists compaction; therefore, very high slump is unnecessary and may cause defects. Selecting an appropriate slump prevents segregation and bleeding.
Given Data / Assumptions:
- Normal reinforced concrete with internal or surface vibrators.
- Self-compacting concrete is excluded.
Concept / Approach:Guides recommend a slump range of about 25–75 mm when vibration is applied. The upper bound 75 mm (7.5 cm) limits the risk of loss of cohesion under vibratory action.
Step-by-Step Solution:Acceptable slump band under vibration ≈ 25–75 mm.Therefore maximum recommended slump ≈ 7.5 cm.
Verification / Alternative check:IS 456 and site best practices align with the 25–75 mm recommendation for vibrated concrete.
Why Other Options Are Wrong:
- 10–15 cm exceed safe limits and risk segregation; 2.5–5 cm are within range but are not the upper limit.
Common Pitfalls:
- Adding water to raise slump when vibrators are available, reducing strength and durability.
Final Answer:7.5 cm