Venturimeter principle – pressure comparison between inlet and throat For an incompressible flow through a properly installed venturimeter, the static pressure at the throat is __________ than the static pressure at the inlet (upstream section).
-
Ahigher
-
Blower
-
Cthe same for all flows
-
Dzero at design discharge
-
Eindeterminate without knowing pipe roughness
Answer
Correct Answer: lower
Explanation
Introduction / Context:Venturimeters infer flow rate from the pressure drop produced as fluid accelerates from a larger upstream area to a smaller throat area. Recognizing the qualitative pressure change across these sections is foundational.
Given Data / Assumptions:
- Steady incompressible flow (e.g., water) in a horizontal meter for simplicity.
- Negligible energy losses between the pressure taps compared to the main acceleration effect.
- No cavitation at the throat (pressure remains above vapor pressure).
Concept / Approach:Bernoulli’s equation states that along a streamline, p/γ + V^2/(2g) + z is approximately constant (minus losses). At the throat, area is smaller, velocity is higher, so velocity head increases. To conserve energy, static pressure head must decrease, hence p_throat < p_inlet.
Step-by-Step Solution:Step 1: Note A_inlet > A_throat → V_throat > V_inlet.Step 2: Apply Bernoulli: increase in V^2/(2g) must be balanced by a drop in p/γ (for equal elevations and small losses).Step 3: Conclude p_throat < p_inlet, producing a measurable differential head.Step 4: Use the differential head with calibration to compute discharge.
Verification / Alternative check:Manometer connections on a venturimeter always show a lower head at the throat limb relative to the upstream limb at any nonzero flow.
Why Other Options Are Wrong:
- Higher or same: violate Bernoulli for accelerating flow.
- Zero at design discharge: pressure is not zero; cavitation would be a concern long before that.
- Roughness: affects loss but not the fundamental trend that throat pressure is lower.
Common Pitfalls:Neglecting elevation differences in inclined installations; always include z terms when necessary.
Final Answer:lower