LaMont boiler: identify whether the statement about type and circulation is correct. Statement: The LaMont boiler is a high-pressure, water-tube steam boiler that operates with forced circulation driven by a pump. Choose the correct option (True/False).

Mechanical Engineering Steam Boilers and Engines Difficulty: Easy
Choose an option
  • A
    True
  • B
    False
  • C
    True only at low pressure
  • D
    False because LaMont is a natural-circulation boiler

Answer

Correct Answer: True

Explanation

Concept & identificationThe LaMont boiler is a high-pressure water-tube boiler that uses forced circulation. A circulating pump drives water through the economiser and evaporator tubes, improving heat transfer and preventing overheating of tubes.

Why True

  • Water flows inside tubes (water-tube construction).
  • A pump forces circulation (not natural circulation).
  • Designed for high pressures and high steaming rates.

Common pitfallsDo not confuse LaMont with natural-circulation types (e.g., Babcock & Wilcox). LaMont explicitly employs a pump.

Final AnswerTrue