Cement testing — water for Vicat initial setting time If P (%) is the water required to produce a paste of normal consistency, what proportion of P should be added when preparing the paste for determining the initial setting time of cement (Vicat apparatus, standard practice)?

Difficulty: Easy

Correct Answer: 0.85 P

Explanation:


Introduction / Context:
Cement setting time tests are fundamental in civil engineering quality control. The Vicat apparatus is used to determine the initial and final setting times. However, the water content used in these tests is not exactly the same as the water for normal consistency; a fixed fraction of the normal consistency value is used to prepare the paste for the initial setting time test.


Given Data / Assumptions:

  • P is the percentage of water that yields a paste of normal consistency, found with the Vicat plunger test.
  • Standard laboratory temperature and humidity conditions are assumed.
  • Ordinary Portland cement without special admixtures is considered.


Concept / Approach:
Standards (commonly taught in construction materials courses) specify that the water used to prepare the paste for the initial setting time test is a fixed proportion of the normal consistency water. Using this proportion ensures comparable penetration behavior of the Vicat needle and reliable determination of the time at which the paste loses plasticity.


Step-by-Step Solution:

Find P from the normal consistency test with the 10 mm to 12 mm Vicat plunger penetration criterion.Compute required water for initial setting time paste as 0.85 * P.Prepare paste quickly, start the stopwatch at water contact, and perform periodic needle penetrations to identify the initial setting time.


Verification / Alternative check:
Using 0.85 P provides a paste a bit stiffer than the one at normal consistency, which is necessary so that the needle penetration decreases within a practical time window, enabling the determination of the initial set.


Why Other Options Are Wrong:

  • 0.70 P, 0.75 P, 0.80 P (A/B/C): too little water, paste will be excessively stiff; penetration will be inadequate and timing unreliable.
  • 0.90 P (E): paste too wet; it delays stiffening and distorts the setting time measurement.


Common Pitfalls:
Confusing the water for normal consistency with the water for setting time tests; delays in mixing and charging the mould also shift results. Always condition cement and water properly and start timing immediately.


Final Answer:

0.85 P