Groundwater hydraulics: For discharge of a confined (artesian) tube well under steady conditions, which classical formula is used?
-
AThiem’s formula
-
BDarcy’s linear head-loss law for laminar flow in porous media only
-
CTolman’s formula
-
DDupuit’s equation for unconfined flow only
-
ENone of these.
Answer
Correct Answer: Thiem’s formula
Explanation
Introduction / Context:Estimating the discharge of tube wells requires groundwater flow theory. For steady, radial flow to a well in a confined aquifer, the classical Thiem equation relates drawdown and discharge. Recognizing which expression applies to which aquifer type is a core hydrogeology skill.
Given Data / Assumptions:
- Confined aquifer of thickness b with transmissivity T = K * b.
- Steady-state pumping with two observation wells at radii r1 and r2 giving piezometric heads h1 and h2.
- Radial flow, Dupuit–Thiem assumptions (horizontal flow in aquifer, negligible vertical gradients).
Concept / Approach:For confined conditions, Thiem’s formula for discharge is commonly written as Q = 2 * π * K * b * (h1 − h2) / ln(r2 / r1) = 2 * π * T * (Δh) / ln(r2 / r1). It stems from integrating Darcy’s law in cylindrical coordinates under steady conditions.
Step-by-Step Solution:
Apply radial Darcy flow: q_r = −K * (dh/dr).Conservation for steady flow: Q = 2 * π * r * b * q_r.Integrate between r1, r2 and h1, h2 to obtain Thiem’s expression for Q.Verification / Alternative check:Plot drawdown versus ln(r); the slope gives Q / (2 * π * T), a standard field method for confined aquifers.
Why Other Options Are Wrong:Darcy’s law is the basis but not, by itself, the discharge formula; Tolman is not the standard reference here; Dupuit’s unconfined form uses heads squared (h^2) rather than linear heads.
Common Pitfalls:Mixing unconfined and confined forms; using base-10 logarithms without converting constants; ignoring well losses and partial penetration effects.
Final Answer:Thiem’s formula