Difficulty: Easy
Correct Answer: 0.577
Explanation:
ConceptThe critical pressure ratio is the downstream-to-upstream pressure ratio at which flow just becomes sonic at the throat (choked flow), giving maximum mass flow for given inlet conditions. For steam, the critical ratio depends slightly on state:
ResultFor initially wet steam, the standard value used in turbine/nozzle calculations is about 0.577.
Common pitfallDo not confuse the superheated value (≈ 0.546) with the wet-steam value.
Final Answer0.577