Hydraulics in continuous reactors — A continuous bioreactor has a dilution rate D = 0.5 h^-1. What is its residence time (space time)?
-
Aln(2) / 0.5 h
-
Bln(2) × 0.5 h
-
C0.5 h
-
D2 h
-
E1 / (ln(2)) h
Answer
Correct Answer: 2 h
Explanation
Introduction:Residence time (also called space time, tau) is a basic hydraulic parameter in continuous reactors. It relates directly to the dilution rate, which is commonly reported in bioprocessing. This question checks your ability to convert between D and tau quickly and correctly.
Given Data / Assumptions:
- Dilution rate D = F / V = 0.5 h^-1.
- Well-mixed reactor at constant volume.
- No cell recycle or volume change.
Concept / Approach:By definition, residence time tau is the reciprocal of the dilution rate for a simple CSTR without recycle: tau = V / F = 1 / D. Natural logarithms appear in unrelated contexts (e.g., half-life in first-order decay), but not in the basic D–tau identity.
Step-by-Step Solution:Start with tau = 1 / D.Insert D = 0.5 h^-1.Compute tau = 1 / 0.5 = 2 h.Cross-check units: h^-1 inverted gives hours.
Verification / Alternative check:Given V and F separately, tau = V / F would yield the same value (e.g., V = 2 L and F = 1 L/h gives tau = 2 h), confirming consistency with 1/D.
Why Other Options Are Wrong:
- (a) and (b) inject ln(2), which is unrelated here.
- (c) 0.5 h corresponds to D = 2 h^-1, not 0.5 h^-1.
- (e) 1/ln(2) h is dimensionally inconsistent with D.
Common Pitfalls:Confusing half-life t_1/2 = ln(2)/k with residence time; mixing up D with k from first-order reactions.
Final Answer:2 h