Assertion–Reason (DC choppers): A class C chopper (two-quadrant) can operate in the first and second quadrants. Reason: A class B chopper operates only in the second quadrant (regenerative quadrant). Select the correct option.

Difficulty: Easy

Correct Answer: Both A and R are correct and R is correct explanation of A

Explanation:

Introduction / Context:DC choppers are classified by the quadrant(s) in which the voltage–current pair (V, I) operates. Understanding quadrant operation clarifies power flow and regenerative capability. This question checks knowledge of Class B and Class C choppers and their quadrant behavior.Given Data / Assumptions:

  • Class B chopper: second-quadrant operation (V > 0, I < 0), energy returns to the source.
  • Class C chopper: combination of Class A and B choppers.
Concept / Approach:Class C is effectively a two-quadrant chopper combining Class A (first quadrant: motoring) and Class B (second quadrant: regenerative braking), enabling current reversal or power flow back to source depending on load and control.Step-by-Step Solution:1) Class B chopper permits energy to flow from load to source with V positive and I negative.2) Class C chopper is a combination of Class A and Class B, hence supports both first and second quadrants.3) Therefore, the reason directly supports the assertion.Verification / Alternative check:Standard chopper classification charts show Class C = A + B (two-quadrant operation).Why Other Options Are Wrong:
  • Options stating R is not the explanation are incorrect because knowledge of Class B behavior explains why Class C covers both quadrants.
  • Options claiming A or R is wrong contradict accepted definitions.
Common Pitfalls:
  • Confusing Class C with Class D (third and fourth quadrants).
  • Assuming Class B allows forward current; it does not.
Final Answer:Both A and R are correct and R correctly explains A.

More Questions from Power Electronics

Discussion & Comments

No comments yet. Be the first to comment!
Join Discussion