Difficulty: Easy
Correct Answer: No, polarity is not important on AC ranges (False statement)
Explanation:
Introduction / Context:
Digital multimeters (DMMs) provide separate AC and DC measurement modes. Confusion about probe polarity on AC can lead to unnecessary mistakes and slow troubleshooting. This question clarifies the correct practice.
Given Data / Assumptions:
Concept / Approach:
On AC ranges, the meter internally processes the alternating waveform (through rectification and scaling, or true-RMS conversion). Since the signal alternates polarity by definition, reversing the probe leads simply corresponds to a 180-degree phase shift that does not change the magnitude reading. Therefore, “maintaining polarity” is not required for standard AC measurements.
Step-by-Step Solution:
Verification / Alternative check:
Oscilloscopes confirm that reversing probes simply flips the sign reference; power meters use magnitude calculations insensitive to lead order for sinusoidal AC.
Why Other Options Are Wrong:
Claiming “always maintain polarity” confuses DC measurement conventions. True-RMS versus average-responding affects accuracy for nonsinusoidal waves, not polarity sensitivity. Ground reference concerns are safety/connection issues, not polarity sensitivity on the meter display.
Common Pitfalls:
Using DC range by mistake (then polarity matters); measuring with floating references in unsafe ways; misinterpreting negative signs on meters that auto-detect DC offsets.
Final Answer:
No, polarity is not important on AC ranges (the original statement is False).